Timeouts, pool sizes and loop pacing are set in code with Tuning. Every value has a measured default, so most apps pass nothing. Set only what you change:

from llm_queue import LLMQueue, StoreOptions, Tuning

llmq = LLMQueue.from_env(tuning=Tuning(store=StoreOptions(read_timeout_secs=20)))

Tuning has four parts: store (StoreOptions), bedrock (BedrockOptions), engine (EngineTimings) and registry (RegistryOptions).

StoreOptions

The Valkey / Redis client of every process. The pool size is LLMQ_STORE_MAX_CONNECTIONS.

Field Default What it does
retries 3 Retries of a failed store command, with jittered backoff (~1.5 s in all)
connect_timeout_secs 5 A store node that does not answer in a failover fails fast
read_timeout_secs 15 A reply that never comes fails the command instead of hanging its call
health_check_secs 30 A connection idle this long is pinged before use
pool_wait_secs 10 A burst waits this long for a free connection

BedrockOptions

The Bedrock and STS clients.

Field Default What it does
read_timeout_secs 300 Bedrock / STS read timeout (each attempt also has attempt_timeout_secs)
connect_timeout_secs 10 Bedrock / STS connect timeout
max_pool_connections 100 Connections per client (one client per account x region)
role_session_secs 3600 Assumed-role session length (900-43200; 3600 is the role-chaining maximum)

EngineTimings

Pacing of the engine's loops.

Field Default What it does
idle_poll_secs 0.05 Idle receive: poll this often ...
idle_slow_secs 1 ... then this often ...
idle_after_empty 20 ... after this many empty polls. A send's doorbell wakes a worker at once
result_recheck_secs 60 A waiting caller's last-resort read of its result
health_probe_secs 3 A store probe slower than this reports "down"
stream_read_block_ms 100 An opened chunk stream joins the shared read within this
admission_probe_wait_ms 200 A breaker's probe call is in flight: check again after this
admission_slot_wait_ms 50 No free slot: retry after this ...
admission_slot_jitter_ms 150 ... plus up to this, at random (spreads the retries)
admission_wait_ms 100 A refusal with no better estimate retries after this
limiter_cut_ms 1000 A throttle cuts the adaptive concurrency limit at most once per this ...
limiter_cut_factor 0.7 ... to this fraction of itself (below 1)
budget_key_ms 180000 Budget and limiter keys live this long (at least 130000: a fixed window spans 2 minutes)

RegistryOptions

Field Default What it does
history_size 20 Registry versions kept for rollback
edit_retries 3 Retries of a live edit that raced another one

Audit retention is LLMQ_AUDIT_RETENTION_DAYS, not a tuning field.

Checks at start-up

from_env refuses bad tuning with ConfigError, every problem listed at once:

  • wrong types, zero or negative values;
  • store.read_timeout_secs must be at least 1 s above idle_slow_secs, LLMQ_QUEUE_WAIT_MS and stream_read_block_ms (each a blocking command), or that command times out;
  • limiter_cut_factor below 1; budget_key_ms at least 130000;
  • idle_poll_secs not above idle_slow_secs;
  • role_session_secs from 900 to 43200 (STS limits).

Circuit breaker timing (registry)

The breaker is tuned per model in the registry, not in Tuning. Each setting can be set on defaults, an account, a model or a deployment:

Setting Default What it does
breaker_threshold 5 Failures that open the breaker
breaker_window_secs 60 Failures count toward the threshold only within this window
breaker_cooldown_secs 15 An open breaker allows one probe call after this
breaker_probe_secs 60 A probe call that never reported back stops blocking others after this

How the breaker moves between states is in Failures and recovery.